Input Characteristics
A.2
Specifications
Output Characteristics
Over-Voltage Protection (OVP)
Input Voltage Range
Min
Nom
Max
Range 1
90V
115V
140V
Range 2
180V
230V
264V
Input Frequency Range
43 Hz to 66 Hz
Maximum Input ac Current
5A max at 115Vac
3A max. at 230Vac, maximum load
Inrush Current
90A cold start
120A warm start
Efficiency
65% min. at nominal input,
maximum load
Output
Load Range
Regulation
Ripple
Voltage
Min
Max
Min
Max
Max
+5V
1.5A
25.0A
-5%
+5%
50mV
p-p
+12V
0.2A
8.0A
-5%
+5%
120mV
p-p
-12V
0A
0.8A
-10%
+10%
120mV
p-p
+5Vsb
0A
2.0A
-5%
+5%
50mV
p-p
+3V3
0A
14.0A
-5%
+5%
50mV
p-p
Output Voltage
Maximum Voltage
+5V
6.5V
+12V
15.6V
+3.3V
4.3V
NOTE
The power supply will shut down and latch off for sh5V,
+12V, -12V, or +3.3V. By sh5Vsb, the power supply can
latch down or automatically recover when the fault condition is
removed.