DS300f G2 Series User Manual
19
fc sAn d
AtA
P
Ath
To establish the data path:
1. Connect FC cables between at least one FC data port on each RAID controller and the FC switch.
See "Figure 2 - 10: FC SAN data and management connections".
2. Connect FC cables between the FC switch and the FC HBA cards in both host PCs or servers.
If you have multiple ASUS DS300f G2 subsystems, repeat steps 1 and 2 as required.
The ASUS DS300f G2 subsystem is shown with SFP transceivers installed.
M
AnAgeMent
P
Ath
To establish the management path:
1. Connect Ethernet cables between the Management ports on both RAID controllers and the network switch.
See "Figure 2 - 10: FC SAN data and management connections".
2. Connect Ethernet cables between the network ports on both host PCs or servers and the network switch.
If you have multiple ASUS DS300f G2 subsystems, repeat steps 1 and 2 as required.
The ASUS DS300f G2 subsystem is shown with SFP transceivers installed.
Figure 2 - 10: FC SAN data and management connections