DS300f G2 Series User Manual
126
M
anaGInG
the
e
nClosure
(Clu)
Enclosure Management includes the following functions:
•
"Viewing the Enclosures Summary (CLU)" on page 126
•
"Viewing Enclosure Information (CLU)" on page 126
•
"Making Enclosur e Settings (CLU)" on page 126
•
"Viewing Power Supply Status (CLU)" on page 127
•
"Locating a Power Supply (CLU)" on page 127
•
"Viewing Cooling Unit Status (CLU)" on page 127
•
"Viewing Temperature Sensor Status (CLU)" on page 127
•
"Viewing Voltage Sensor Status (CLU)" on page 127
•
"Viewing Battery Information (CLU)" on page 128
•
"Locating an Enclosure (CLU)" on page 128
v
IewInG
the
e
ncloSureS
S
ummary
(clu)
Enclosure Management includes information, status, settings and location. To access Enclosure Management:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
The following information is shown:
• Enclosure ID number
• Enclosure Type
• Operational Status
• Status Description (specific components in need of attention, if any)
v
IewInG
e
ncloSure
I
nformatIon
(clu)
To view enclosure information:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
You can monitor power supplies, cooling units, enclosure temperatures and voltages, and the battery.
A
dJustAble
iteMs
You can set or adjust the following items:
•
Enclosure Warning and Critical temperature thresholds
•
Controller Warning and Critical temperature thresholds
See “Making Enclosure Settings” below.
For information on Enclosure problems, see "Enclosure Problems" on page <?>.
m
akInG
e
ncloSur
e
S
ettInGS
(clu)
To make Enclosure settings:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Enclosure Settings
and press
Enter
.
5. Highlight the Temperature Warning threshold you want to change.
6. Press the backspace key to erase the current value.
7. Type a new interval value in degrees C.
8. Press
Control-A
to save your settings.
Summary of Contents for DS300 G2 Series
Page 1: ...ASUS Storage DS300 G2 Series ...
Page 11: ......
Page 34: ......
Page 38: ......
Page 262: ......