DS300f G2 Series User Manual
128
4. Highlight
Voltage Sensors
and press
Enter
.
If any voltage is outside the Healthy Threshold values, there is a voltage malfunction in the enclosure.
See "Diagnosing an Enclosure Problem" on page <?>.
v
IewInG
b
attery
I
nformatIon
(clu)
This feature enables you monitor and recondition the subsystem battery or batteries.
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Batteries
and press
Enter
.
5. Highlight the battery you want to monitor and press
Enter
.
b
Attery
n
otes
If a battery does not reflect normal conditions and it is not currently under reconditioning, run the Recondition
function before you replace the battery. See Reconditioning a Battery (CLU).
Reconditioning fully discharges, then fully recharges the battery. During reconditioning, if the Adaptive Writeback
Cache function is enabled, the controller cache is set to
Write Thru
. After reconditioning, the cache is reset to
Wr
ite Back. See "Making Controller Settings (CLU)" on page 124.
If a battery reaches the threshold temperature while charging or discharging, the charge or discharge pauses
and the blower runs at high speed until the battery temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the battery. See "Replacing a Cache
r
econDItIonInG
a
b
attery
(clu)
To recondition the subsystem battery:
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Batteries
and press
Enter
.
5. Highlight the battery you want to recondition and press
Enter
.
6. Highlight
Start Reconditioning
and press
Enter
.
7.
Press Y to confirm.
Reconditioning fully discharges, then fully recharges the battery. During reconditioning, if the Adaptive
Writeback Cache function is enabled, the controller cache is set to
Write Thru
. After reconditioning, the
cache is reset to
Write Bac
k. See "Making Controller Settings (CLU)" on page 124.
l
ocatInG
an
e
ncloSure
(clu)
This feature helps you identify the physical ASUS DS300f G2 enclosure you are working with through the CLU.
1. From the Main Menu, highlight
Subsystem Management
and press
Enter
.
2. Highlight
Enclosure Management
and press
Enter
.
3. Highlight the enclosure you want and press
Enter
.
4. Highlight
Locate Enclosure
and press
Enter
.
The LEDs on the front of the ASUS DS300f G2 blink for one minute.