DS300f G2 Series User Manual
131
on page 135. After rebuilding, the drive shows Stale. Run
Clear Stale
then run
Clear PFA
.
If the physical drive with a PFA error is a spare, you must delete the drive as a spare, then
Clear PFA
is
available.
After you clear a PFA error, watch for another PFA error to appear. If it does, replace the physical drive.
f
orcInG
a
P
hySIcal
D
rIve
o
fflIne
(clu)
This function enables you to force an online physical drive to go Offline.
The Force Offline function appears only for physical drives that are assigned to disk arrays.
Caution
Forcing a physical drive offline is likely to cause data loss. Back up your data before
you proceed. Use this function only when required.
Important
Forcing a physical drive offline causes your logical drives to become degraded. If Auto
Rebuild is enabled and a spare drive is available, the disk array begins rebuilding itself
automatically.
To force a physical drive offline:
1. From the Main Menu, highlight
Physical Drive Management
and press
Enter
.
2. Highlight
Global Physical Drives Settings
and press
Enter
.
3. Highlight the physical drive you want and press
Enter
.
4. Highlight
Force Offline
and press
Enter
.
5.
Press Y to confirm.
l
ocatInG
a
P
hySIcal
D
rIve
(clu)
This feature helps you identify a physical drive within the ASUS DS300f G2 enclosure you are working with
through the CLU. To locate a physical drive:
1. From the Main Menu, highlight
Physical Drive Management
and press
Enter
.
2. Highlight
Global Physical Drives Settings
and press
Enter
.
3. Highlight the physical drive you want and press
Enter
.
4. Highlight
Locate Physical Drive
and press
Enter
.
The drive carrier status LED flashes for one minute.
Figure 5 - 5: Drive carrier status LED
Drive Status LED
Power/Activity LED
Summary of Contents for DS300 G2 Series
Page 1: ...ASUS Storage DS300 G2 Series ...
Page 11: ......
Page 34: ......
Page 38: ......
Page 262: ......