DS300f G2 Series User Manual
137
M
anaGInG
s
pare
d
rIves
(Clu)
Spare Drive Management includes the following functions:
•
"Viewing a list of Spare Drives (CLU)" on page 137
•
"Creating a Spare Drive (CLU)" on page 137
•
"Making Spare Drive Settings (CLU)" on page 137
•
"Running Spare Check (CLU)" on page 138
•
"Deleting a Spare Drive (CLU)" on page 138
v
IewInG
a
lISt
of
S
Pare
D
rIveS
(clu)
To view a list of spare drives:
From the Main Menu, highlight
Spare Drive Management
and press
Enter
.
A list of the current spare drives appears, including the following parameters:
•
ID number
•
Operational Status
•
Physical Drive ID number
• Configured Capacity
•
Revertible
– The spare drive returns to spare status after you replace the failed
drive in the disk array. See “Transition” on page 356 for more information.
•
Type
– Global (all disk arrays) or Dedicated (to specified disk arrays)
•
Dedicated to Array
– The array to which a dedicated spare is assigned
For more information, see "Disk Arrays" on page <?>.
c
reatInG
a
S
Pare
D
rIve
(clu)
Only unconfigured physical drives can be used to make spares. Check your available drives under Physical Drive
Management. Also see "Managing Physical Drives" on page <?>.
1. From the Main Menu, highlight
Spare Drive Management
and press
Enter
.
2. Highlight
Create New Spare Drive
and press
Enter
.
A default physical drive is shown with possible alternative choices.
3. To choose different drive, highlight the drive, press the backspace key to remove the current number, then
type a new number.
4. Highlight R
evertible
and press the spacebar to toggle between
Yes
and
No
.
A revertible drive can be returned to spare status after you replace the failed drive in a disk array. See
"Transition" on page <?> for more information.
5. Highlight
Spare Type
and press the spacebar to toggle between
Dedicated
and
Global
.
Dedicated means this spare drive can only be used with the specified disk arrays. Global means this
spare drive can be used by any disk array.
If you chose Dedicated, a default disk array is shown with possible alternative choices.
To choose different array, highlight the array and press the backspace key to erase the current number,
then type the new number.
6. Press
Control-A
to save the spare drive.
m
akInG
S
Pare
D
rIve
S
ettInGS
(clu)
To change spare drive settings:
1. From the Main Menu, highlight
Spare Drive Management
and press
Enter
.
A list of the current spare drives appears, including the following parameters:
2. Highlight the spare drive you want to change and press
Enter
.
3. Highlight the setting you want to change:
•
Revertible
– A revertible drive can be returned to spare status after you replace the
failed drive in a disk array. See “Transition” on page 356 for more information.
•
Type
– Dedicated means this spare drive can only be used with the specified disk
arrays. Global means this spare drive can be used by any disk array.
4. Press the spacebar to toggle between the choices.
5. For dedicated spares, type the array number the spare is assigned to.
6. Press
Control-A
to save your settings.
Summary of Contents for DS300 G2 Series
Page 1: ...ASUS Storage DS300 G2 Series ...
Page 11: ......
Page 34: ......
Page 38: ......
Page 262: ......