GigaX Series L2 Managed Switch User’s Guide
54
Security Model: enter the Security Model Name that the Group belongs.
Any is suitable for v1,v2,v3. USM is SNMPv3 related.
Security level: enter the Security level Name that the Group belongs. Only
NoAuth, AuthNopriv, AuthPriv can be chosen.
Click on the
when you create a new VACM group entry by the
above information. Then you will see the new added entry shows in the group
window. You can remove the existed group by selecting the entry with the
mouse, then clicking on
. The
button updates the existed
VACM Group entries. Click
to save effectively. Click
to
refresh the settings to current value. To make the configuration effective,
please go to "Save Configuration" page, then click on
.
Figure 31. VACM Group
4.6.5 VACM
View
VACM (View-based Access Control Model) View is used to view the
information of SNMPV3 VACM Group
.
View Name: enter the security group name.