5-12
Chapter 5: RAID configuration
Select a destination disk with the same size as the original hard disk.
[
DEGRADED VOLUME DETECTED
]
[
↑↓
]-Previous/Next [ENTER]-Select [ESC]-Exit
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XX.XGB
5.2.7
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as “
Degraded
” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager
option ROM utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select
the destination disk or press <ESC> to exit.
5.2.6
Exiting the Intel
®
Matrix Storage Manager
To exit the utility
1.
From the utility main menu, select
5. Exit
, and then press <Enter>. The
following warning message appears.
2.
Press <Y> to exit or press <N> to return to the utility main menu.
Are you sure you want to exit? (Y/N):
[
CONFIRM EXIT
]
Summary of Contents for P7F-C
Page 1: ...Motherboard P7F C Series P7F C SAS P7F C 4L ...
Page 23: ...ASUS P7F C Series 2 5 2 2 3 Motherboard layout P7F C SAS ...
Page 24: ...2 6 Chapter 2 Hardware information P7F C 4L ...
Page 52: ...2 34 Chapter 2 Hardware information ...
Page 96: ...4 40 Chapter 4 BIOS setup ...
Page 150: ...5 54 Chapter 5 RAID configuration ...
Page 179: ...ASUS P7F C Series A 3 A 1 P7F C SAS Series block diagram ...
Page 180: ...A 4 Appendix A Reference information A 2 P7F C 4L Series block diagram ...