ASUS PIKE 6480
2-9
2.2.4
Spare Management
You may configure one disk as a global hot spare to protect critical data on RAID
set(s). You may create the hot spare disk before or after you create a RAID set.
Refer to this section when adding a hot spare disk on an existing volume.
If a disk on a RAID set fails, the utility automatically rebuilds the failed disk
data on the hot spare. When the failed disk is replaced, the utility assigns the
replacement as the new hot spare.
To create a hot spare
1. From the utility menu bar, select
RAID > Spare Management
, and then
press <Enter>. The
Spare Management
screen appears.
Marvell BIOS Setup (c) 2008 Marvell Technology Group Ltd.
ENTER/SPACE:Select, ESC:Back/Exit
[Selection]
[Controller]
[ Devices ]
[ RAID ]
RAID Config
Spare Management
Port Disk Name Size Max Speed Status
0 SAS : ST3146855SS 139.9GB SAS 3.0 FREE
NEXT
2. Select a desired drive to create a hot spare. Select
NEXT
,
and then press
<Enter>. Press <Y> after the confirmation screen appears.
Marvell BIOS Setup (c) 2008 Marvell Technology Group Ltd.
[Selection]
[Controller]
[ Devices ]
[ RAID ]
RAID Config
Set spare?[Y]
Spare Management
Port Disk Name Size Max Speed Status
*0 SAS : ST3146855SS 139.9GB SAS 3.0 FREE
NEXT
3. Press <ESC> to exit the
Spare Management
screen.
Summary of Contents for PIKE 6480