Node link
2.4.3.
The RS 485 Node link is a manual
switch to change the address of the
Asycube. The following rules have to
be respected to guarantee a proper
behavior.
1)
RS-232 Mode: Node must be set
to 0.
2)
RS-485 Mode: Node must be set
to a value from 1 to F
Figure 2-14 : Node link
set on value “2”
Power connection
2.4.4.
WARNING !
-
Before supplying power to the Asycube, check that your distribution voltage is the same
as the nominal voltage.
-
Never disconnect the power cables. Always turn the machine off and then cut the power
XS601 (.)
Signal description
XS601 (1)
+24VDC
XS601 (2)
0V COM
In case of full vibrating power X, Y, Z,
Bulk and the Motor (not available for
Asycube Y600 830 008) the current
increases to 4.2A
Characteristic
Value
Voltage
+24V DC + 5%
Current
3 A
… 4.2 A
Figure 2-15 : power connection
XS601 (2)
XS601 (1)