background image

 

 

 

Operation Manual Touchscreen 

 

Applies to all cabinets of the -24, -54 and -57 

series with Touchscreen 

(From LOGO software version upward of 1-24) 

 

 

OPERATING THE DEVICE 

All mechanical and electrical connections should be checked for tight fit and tightness prior to

 

 

 

 

 

 

 

 

 

   

 

 

   

commissioning, as well as to remove any soil. 

 

Insert the plug into a grounded electrical outlet. If the device does not start instantly, it is in the

 

 

 

   

 

 

   

 

 

 

 

 

       

 

standby state. Please press the activation icon on the screen. 

 

The initialization program of the cabinet now starts. When the initialization is complete, the display

 

 

   

 

 

 

 

 

 

   

 

 

 

shows the home screen and the fans start running. 

 

 

Summary of Contents for Totech EU SUPER DRY U-5003 I-3315003

Page 1: ...uld be checked for tight fit and tightness prior to commissioning as well as to remove any soil Insert the plug into a grounded electrical outlet If the device does not start instantly it is in the standby state Please press the activation icon on the screen The initialization program of the cabinet now starts When the initialization is complete the display shows the home screen and the fans start...

Page 2: ...1 2 HUMIDITY ALARM LIMIT 8 6 1 2 1 ALARM 8 6 1 3 HUMIDITY ALARM DELAY 8 6 1 4 SETPOINT TEMPERATURE 8 6 1 5 TEMPERATURE DEVIATION 8 6 1 6 TEMPERATURE ALARM DELAY 8 6 1 7 Diagnose 8 6 2 SETTINGS 2 4 9 6 2 1 OFFSET LOCK FIRMWARE 9 6 3 SETTINGS 3 4 10 6 3 1 SYSTEM TIME DATA LOGGER 10 6 4 SETTINGS 4 4 11 MANUAL REGENERATION AND REGENERATION TIMER 11 7 LANGUAGE 11 8 STANDBY 12 9 DATA LOGGING 12 10 CALIB...

Page 3: ...unication error via Ethernet 15 14 4 Display indicates BM no resp Press ESC 15 14 5 No indication on Display 15 14 6 Logic module and extension module checking 15 14 7 Humidity too high 16 14 8 Temperature too low 16 15 Warranty and Liability 17 15 1 Warranty and liability 17 15 5 Guidelines for the RMA procedure of Totech Europe B V 18 16 Serial numbers 19 16 1 Cabinet serial numbers 19 16 2 Dry ...

Page 4: ... direct comparison 1 1 Regeneration When the display is reading Regeneration in yellow in the top left corner the program has started a regeneration of the desiccant material inside the drying unit The humidity alarm light optional signals this state with a flashing green signal After completion of the regeneration the device switches to the drying mode which is signaled by a green continuous sign...

Page 5: ...tical and acoustic alarm can be acknowledged with the Quit alarm button 3 2 FLT RESET With the reset function of the floor lifetime of electronic components you have the possibility to automatically determine the rest time by means of the component specification After entering the Floor Lifetime reset menu by pressing FLT Reset you have to specify some values First of all determine the place of th...

Page 6: ... alarm limits The zoom buttons allow you to adjust the displayed time window To scroll to the past you must stop the current recording with Stop They can then move with the arrow keys in the time axis Press the Start button to return to the current trend display In the right hand window you will find the displayed setpoints with arrows and the remote display at the bottom as well as a bar graph fo...

Page 7: ...settings white representation of the values or by entering the security code via Enter to set the values blue representation of the values In the delivery state no password is assigned so you enter the settings directly with Enter 6 1 SETTINGS 1 4 On the first page you can set the setpoints for humidity and temperature If you click on the current value an input window opens Here you can change the...

Page 8: ...e acoustic alarm can be acknowledged by pressing the Alarm button followed up with Quit Alarm This is then active again when the alarm is re activated The alarm message in the display and the traffic light message are automatically ended after elimination of the alarm cause 6 1 3 HUMIDITY ALARM DELAY To ensure that every short term increase in the humidity does not trigger an alarm the alarm delay...

Page 9: ...h can be used to protect the setting values On this page is the USB Boot function If you have inserted a program update on a USB memory stick you can carry out the transfer by pressing this button After pressing the display reboots and uses the firmware which is on the USB stick for this startup This is simultaneously transferred into the memory of the display and overwrites the last current firmw...

Page 10: ...value to be changed under Set system time and enter the desired value in the input window In addition to the setting for the acoustic alarm in the display you can deactivate the logging function here as well See 9 Data Logging The Offline button is used to stop the program and you will be taken to the setting functions of the display itself Here you can set the IP address and many other functions ...

Page 11: ...tically If this is not desired the dynamic regeneration on the service menu has to be deactivated With Manual Regeneration the user can start an immediate regeneration This function is only available during the drying phase The man Reg button initiates a regeneration The necessary strength of the regeneration is determined automatically 7 LANGUAGE In the menu you will find the Language option Here...

Page 12: ...gram can be used by Windows The free Totech Viewer offers the ability to download the data graphically 10 CALIBRATION Totech recommends to check the calibration once a year or to recalibrate the system by replacing the sensor To calibrate the sensor we recommend the following two possibilities 1 Replacing the sensor by a factory calibrated sensor After detaching the screw fastened retaining ring t...

Page 13: ... Operation Manual Touchscreen ...

Page 14: ...owing steps you ll need to have the cabinet connected to the network You can also connect the cabinet directly to a PC or laptop using an Ethernet cable Make sure that the PC or laptop running the Totech Viewer software is set in the same range as the current IP address of the cabinet before changing the IP address or it won t work Open the software press File Download data Refresh The software wi...

Page 15: ... the dehumidifier overall measuring Additional measurement equipment or software is not required 2 Define deviations by means of a calibrated reference dew point meter minimum accuracy 0 2 RH or higher and calibrate the sensor via the software s calibration function This proceeding requires data connection to PC and software for detailed instructions please refer to the Software Manual of the manu...

Page 16: ...em 9 6 14 5 No indication on Display Check plug connections Check mains fuse in port and replace if necessary Check LED for illumination on power supply unit a No LED illuminated check input side power supply unit 230VAC if present the logic module needs to be replaced b Red LED illuminated disconnect secondary power supply unit If red color remains the power supply unit is to be replaced c If ill...

Page 17: ...heck the cabinet for any leakage check the doors and any open connections to the environment Check if the cabinet is fully loaded with wet components the cabinet needs time to dry these components Insufficient air flow convections vents covered Fan failure replace drying unit 14 8 Temperature too low Heating module switched off switch on heating module Heating module power supply interrupted check...

Page 18: ...the end user The defective part has to be returned after it is replaced with the new one Actual replacement is done by the end user with support from Totech technical support if needed Exchange warranty valid during the second year after purchase of the new product Only U 5000 series U 7000 series Exchange warranty The end user will receive the defective part at a lower price The old part will be ...

Page 19: ...nd or repair parts as soon as possible Shipping the parts to Totech Europe B V Each part must have its own RMA form attached All parts must be shipped back in original packaging as much as possible and ESD safe Those parts that are returned to Totech EU without any proper packaging will not be accepted for warranty or repair Broken or damaged parts due to shipping or bad packaging will not be acce...

Page 20: ...l Touchscreen 16 Serial numbers 16 1 Cabinet serial numbers Explanation how the serial number of the cabinet is identified 16 2 Dry unit serial numbers Explanation how the serial number of the Drying Unit is identified ...

Page 21: ...re fitted with U 5003 Drying Unit MSD 1222 54 HSD series XSD series XSDB series XSDC series XSDR series SDR series confirm that the drying cabinet described corresponds with the fundamental safety and health demands of the following EC instructions EN55011 1998 A1 1999 A2 2002 EN61000 6 2 2001 2006 95 EG 2004 108 EG Totech Europe B V Gerhard Kurpiela ...