2. ALARM
If an alarm is triggered, the display background flashes red. Use the [Alarm] key to go to the alarm
display. All alarms with date, time and type are recorded from start to end.
Press [Alarm Acknowledge] to reset the alarm delay. The optical and acoustic alarm signal switches
off. If the alarm is still active, the alarm activates again after the set delay time.
The alarm delay for the door alarm is preprogrammed to 90 seconds and can not be changed.
The alarm indication in the display and the alarm light indication (option) are automatically deleted
after elimination of the alarm cause. Use the arrows to scroll through the alarm messages.
Use [Delete] to delete the complete alarm list.
3. TIMER (OPTION)
3.1 COUNTDOWN
The countdown timer allows to change the humidity and temperature values for a limited time.
Specify the temporary values and settings and press [Next] to enter the timer. Here you can set the
time, start, stop and reset the countdown. When the timer has elapsed, you will automatically return
to the timer screen. The alarm will go off after the timer has finished. The optical and acoustic alarm
can be acknowledged with the [Quit alarm] button.
3.2 FLT-RESET
With the reset function of the floor lifetime of electronic components, you have the possibility to
automatically determine the rest time by means of the component specification.
After entering the Floor Lifetime reset menu by pressing [FLT-Reset] you have to specify some values.
First of all, determine the place of the components in the cabinet. By default there is room to specify
10 different components. Select the place of the component by pressing the number. The column will
get highlighted in white. Select the housing body thickness [thick], IPC-Level [level] and the
conditions under which the components are drying with [Reset conditions]. The display will
automatically calculate the time needed for the component to dry. After entering all the needed
information for the component, make sure the column is still highlighted and press [Set]. The time will
be set under [(time) left]. Press [Start] and the timer for that component will start. After starting the
timer you can leave the timer display with [Home]. The home screen will show “Timer active” to show
that the timer is running. When the timer has finished you will be automatically returned to the
FLT-Reset menu.
(NOTE: During an active timer, you won’t be able to change any [Settings])