Instructions
Assembly Instructions
Complete systems supplied by Delta-T
The complete BS5 system is supplied with a 3m cable and two stainless
steel V-bolts for mounting. This enables it to be fitted to the mast of the
Delta-T Weather Station, or to any vertical post less than 55mm in
diameter.
Alternatively dispense with the V-bolts for mounting the backing plate
directly to any vertical surface.
The housing is designed for indoor or outdoor use. It is designed to
‘breathe’, and should not be totally immersed or flooded with water.
See also
Climatronics User Manual rev F, section 3.0 INSTALLATION
Measurement Range Set-Up
Two sets of DIP switches control the analogue output voltage and the
range of the sensor. These will need to be changed depending on the
logger used to measure the sensor and the range and accuracy of the
readings. Greater resolution can be achieved when measuring a smaller
range of pressure, this can be selected using the lower and upper limits.
Figure 4. SW1 & SW2 DIP Switches