Number and cross section
of Power cord wires
Power cord
type
Connection type
Current limiter
settings
3x1,5 mm²
H05V2V2-F
1 phase, 1 neutral conductor
1x16A
3x1,5 mm²
H05V2V2-F
1 phase, 1 neutral conductor
1x13A
3x1,5 mm²
H05V2V2-F
1 phase, 1 neutral conductor
1x10A
3x1,5 mm²
H05V2V2-F
1 phase, 1 neutral conductor
1x06A
Voltage between line and neutral conductor must be 220–240 V~.
1 phase, 1 neutral conductor (220–240 V~, 50-60 Hz)
L
= black/brown
N
= blue
= yellow-green
For appliance types: BI1CA…, BI6CA…, BI6CB…, BI7CA…, BI8CA…, BI8CB…, BI9CE…
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between line and neutral conductor must be 220–240 V~. Voltage between lines must be
380–415 V~. Power cord core cross sectional area should be at least as listed in Table for the
following current limiter settings which should be adjusted to your circuit breakers:
Number and cross section
of Power cord wires
Power cord
type
Connection type
Current limiter
settings
4x1,5 mm²
H05VV-F
2 phases, 1 neutral conductor
2x16A
4x1,5 mm²
H05VV-F
2 phases, 1 neutral conductor
2x13A
4x1,5 mm²
H05VV-F
2 phases, 1 neutral conductor
2x10A
4x1,5 mm²
H05VV-F
2 phases, 1 neutral conductor
2x06A
5x1,5 mm²
H05VV-F
2 phases, 2 neutral conductors
(only for NL)
2x16A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x32A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x25A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x20A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x16A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x13A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x10A
3x4,0 mm²
H05VV-F
1 phase, 1 neutral conductor
1x06A
53
Electrical installation