DCP Communications Process Error Messages
5150
(DCP_SYSERR) MAJOR
<string> FAILED for <string>, errno: <integer>
The DCP communications process encountered a system error while
trying to access a file. The value of errno indicates the error reason.
•
Check the file or directory named in the error message. It may
be corrupted.
•
Ensure that the / and /usr file systems are not out of free space.
•
There may be a damaged file system (use fsck when the system is
at single user level) or disk/disk controller problem.
•
Contact your field service representative for assistance.
5151
(DCP_ENOENT) MAJOR
<string> is missing
The DCP communications process attempted to access a nonexistent
file.
•
Contact your field service representative for assistance.
5152
(DCP_BADFORM) MAJOR
<string> badly formatted <string>
The DCP communications process could not use a file because it was
not formatted correctly. A software problem or a file system problem
may exist.
•
Contact your field service representative for assistance.
5153
(DCP_STARTUP) CRITIC
startup failed
The DCP communications process could not start up properly.
•
Contact your field service representative for assistance.