>
If no jack field is used to connect the CO lines to
the network interface, connect new CO lines
directly to the appropriate jacks on the line
modules.
See “Testing Outside Lines” on page 2-103 for
instructions on testing the line jacks for dial tone.
9 Connect any new station wiring as follows as
appropriate:
>
Connect new station wiring runs to their
appropriate jacks in the jack field if one has been
used. Connect the jacks in the jack field to the
proper station ports on the station modules.
> If no jack field is used, connect the station wiring
runs to their appropriate station ports on the station
modules.
See “Testing the System” on page 2-100 for
instructions on testing the voice terminal jacks for dial
tone.
10 Connect any new stations to their wiring runs. See
“Connecting the Voice Terminals” on page 2-92 for
instructions.
11 Add a printer to the control unit if needed. See
“Connecting a Printer to the Control Unit" on page
2-81 or “Connecting a Printer to the Control Unit 50 or
More Feet Away” on page 2-86 for instruction.
12 Add new adjunct equipment as needed. See “Adding
Accessories" on page 2-117 for instructions.
13 Power up the system turning on the Expansion Carrier
first, any Auxiliary Power Units next and the Basic
Carrier last.
Turn to ‘Administering an Upgraded System” on page
3-62 to complete the installation
Upgrading an Existing System
2-137
Summary of Contents for administration and
Page 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Page 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Page 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Page 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Page 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...