24
25
26
> If you
hear a dial tone and connot break it, go to step
24.
> If you
do not hear dial tone, go to step 19.
Connect a
craft set between leads T and R. Select the
tie line being tested using station B. The transmitting
end should provide dial tone.
> If you hear dial tone and can break it, go to step 8
and select the next tie line for testing.
> If you do not hear dial tone, or you hear dial tone
and cannot break it, go to step 19.
Readminister port 1 for Type 5 Simplex.
Print out the tie line translation and make sure that all
the ports are configured for Type 5 Simplex.
> If the tie lines are translated correctly according to
Form 1b, testing is complete.
> If the tie lines are not translated correctly, repeat
step 4 through 6.
Line Troubleshooting 4-29