Installing a Basic
Telephone Module
CONNECTING A
PRINTER TO THE
CONTROL UNIT
If you are installing a Basic Telephone Module, you also
need to install a Frequency Generator in the Power Supply
Module. A Frequency Generator is required for each
carrier that has one or more Basic Telephone Modules. If
possible, place all Basic Telephone Modules on the same
carrier. For additional information, refer to the procedure,
“Installing a Frequency Generator in the Power Supply
Module,” on page 2-67.
NOTE:
Basic Telephone Modules are not intended for
use with an IROB.
Install the Basic Telephone Modules as follows:
1 Review Form lc, System Form—Module
Identification Diagram for Release 3 or Master
Planning Form, Module Location Diagram for Feature
Modules 1 and 2 to determine which carriers have
Basic Telephone Modules.
2 Install the Basic Telephone Modules on the carrier.
A printer (AT&T models 475/476, 572) can be connected
to the control unit through the SMDR port on the
Processor Module.
NOTE:
The AT&T 570 printer is not compatible with the
MERLIN II system because it is not a serial
printer.
The following items are required for installation:
●
EMI Filter (Z200A)
●
Adapter (355AF) for male connector on interface cable
or
●
Adapter (355A) for female connector on interface
cable
Installing the Control Unit 2-81
Summary of Contents for administration and
Page 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Page 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Page 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Page 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Page 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...