LIGHTS, SPEAKER,
Symptom: There is trouble with voice terminal lights,
RINGING PROBLEMS
speaker, and/or ringing.
Possible Cause
1. A faulty control unit or
Power Supply Module.
Possible Solution
Analog set: Slide the T/P
switch on the left side of the
voice terminal
to
the T
position and hold it there if
necessary. If all the red and
green lights flash alternately
and a tone sounds
continually, the analog set is
working properly.
Digital set with data stand:
Turn the voice terminal over
and press the recessed Self-
Test button on the data stand
with a pointed object such as
a straightened paper clip. If
the lights come on but do not
flash. The digital set is
working properly.
If some (but not all) of the
lights flash continually
and/or a tone sounds at
irregular intervals, the
trouble is caused by the voice
terminal or the cable
connection.
If all lights are off and a tone
sounds continually or
irregularly the trouble is
caused by the control unit,
the voice terminal, or the
cable connection.
(continued)
To Investigate Further
G
O
to Possible Cause 3.
Go to Possible Cause 3.
Go to Possible Cause 2.
Go to Possible Case 2.
Procedures for Specific Symptoms
4-41
Summary of Contents for administration and
Page 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Page 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Page 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Page 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Page 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...