MERLIN LEGEND System Programming
Step Instruction
MLX-20L
PC
1.
Enter programming mode.
[Menu]
[S][P][M]
[Enter]
[any key]
Sys Program
[F1]
Exit
[F5]
2. Select Options.
Options
[F7]
3. Select Transfer.
Transfer
[F1]
4. Select Transfer Return Time.
Return Time
[F1]
5. To erase current number of
[Drop]
rings.
[Alt] + [P]
6. Enter number of rings before
[n]
[n]
calls are transferred to
Enter
[F10]
originator.
7. Return to previous menu.
VMS Transfer Return Interval
Exit
[F5]
The VMS Transfer Return Interval defines the number of rings that occur
before a call transferred by the MERLIN MAIL—ML system is redirected to a
designated extension. Calls can be redirected to the QCC queue (hybrid/PBX
mode only), another extension, or a calling group. For more detail, see
“Redirecting Calls Sent to Unassigned Extensions” later in this chapter.
Group-Assigned Features
4-5
Summary of Contents for MERLIN MAIL
Page 13: ...Contents GL Glossary GL 1 IN I n d e x IN 1 vi...
Page 64: ...MERLIN MAIL ML System Programming Figure 3 1 MERLIN MAIL ML System Programming Menus 3 2...
Page 151: ...MERLIN LEGEND System Programming Figure 4 3 Immediate Call Handling Call Handling Methods 4 15...
Page 161: ...MERLIN LEGEND System Programming Figure 4 4 Delayed Call Handling Call Handling Methods 4 25...