MERLIN LEGEND System Programming
Confirming the Touch-Tone Duration
The Touch-Tone Duration defines the duration of touch-tone signals sent
between the MERLI
■
Verify the
(ms).
N LEGEND and MERLIN MAIL—ML
Touch-Tone
Step Instruction
systems.
Interval factory setting of 100 miIliseconds
MLX-20L
PC
1 . Enter programming mode.
[ M e n u ]
[S][P][M]
[ E n t e r ]
[any key]
Sys Program
[ F 1 ]
Exit
[ F 5 ]
2. Select Auxiliary Equipment.
AuxEquip
[ F 9 ]
3. Select VMS/AA.
VMS/AA
[ F 6 ]
4. Select Touch Tone Duration.
TT Duration
[ F 2 ]
5. Verify factory setting of 100
milliseconds.
If the setting is not correct,
erase the current setting.
[Drop]
[Alt] + [P]
To change the setting, type
[nnn]
[nnn]
the number of milliseconds.
Enter
[F10]
6. To return to previous menu,
Exit
[ F 5 ]
Optional System Features
4-35