Air Supply
Drain Daily
Regulator
Filter
Nipple
Lubricator
Quick Coupler
Whip Hose
Nipple
Leader Hose
Do Not Install
Quick Coupler
Here
Typical Air Supply Instal
ůĂƟon
Loading and Operation:
WARNING:
Ensure you read, understand and apply safety instructions before use.
1. Connect the tool to the air hose.
2. Press the trigger to operate the tool.
3. The flow of air may be regulated by adjusting flow valve at the base of the handle.
DO NOT
use any additional force upon the tool.
DO NOT
allow tool to free run for an extended period of time as this will shorten its life.
Maintenance:
WARNING:
Disconnect wrench from air supply before changing accessories, servicing or performing maintenance. Replace or
repair damaged parts. Use genuine parts only. Non-authorized parts may be dangerous.
1. Lubricate the air tool daily with a few drops of air tool oil dripped into the air inlet.
2. Clean the tool after use.
DO NOT
use a worn or damaged tool.
3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line: Moisture or restriction in the air pipe or Incorrect size or type of hose connectors.
To remedy check the air supply.
b) Grit or gum deposits in the tool may also reduce performance. If your model has an air strainer (located in the
area of the air inlet), remove the strainer and clean it.
4. When not in use, disconnect from air supply, clean tool and store in a safe, dry, childproof location.