31 32
F1 500mA/250 FUSE
F2 20A/250V FUSE
9V Batte
9V Battery Door
9V Battery Door Screws
Rear cover screws
Rear cover screws
WARNING
: To avoid electric shock, do not operate your meter until
the fuse door is in place and fastened securely.
Trouble Shooting
1. Meter will not turn ON.
Check the battery contacts for a tight fit.
Check for a minimum battery voltage of 8.0 volts.
2. Ampere reading is erratic or there is no reading at all.
Disassemble the meter back cover as per the fuse
replacement instructions on page 36 and test the fuses for
continuity with another meter.
3. Meter reading is erratic.
Printed circuit board damaged from handling with hands.
Low battery.
“Blown” fuse.
Open circuit in a test lead (frayed or broken wire).
4. Meter readings do not change.
“Hold” feature is still toggled ON.
WARRANTY INFORMATION:
This product is warranted to be free of defects for one year.
If this product fails during the first 12 months due to faulty material
or workmanship, it will be replaced or repaired free of charge, at
the discretion of the manufacturer.
NOTE: this one year warranty does not cover dead batteries
and blown fuses.
For warranty service and coverage, please return this product
to your supplier for processing and evaluation. OR, return it
directly to:
Electronic Specialties, Inc.
139 Elizabeth Ln.
Genoa City, WI 53128
262-279-1400
Defective units being returned to your supplier or to the factory
should include proof of purchase date
.
Any testers that do not function due to misuse or abuse will be
subject to “out of warranty service charges”.