5.2. Instructions For Safe Connection Of The Machine To The Power Source
5.2.1.The three-phase electrical cable socket must have five inputs to the cable on the machine.
5.2.2.Use a connection cable sockets in accordance with the CE Safety Directives.
5.2.3.Check the inlet power supply before powering the machine.
The socket connections have to be made by a qualified electrician, the rotation direction of the saw
blade has to be observed by starting the machine. If the saw blade rotates in reverse direction, the socket
connections have to be checked and re-connected properly. If the direction of rotation of the saw blade is
reversed, it is dangerous to Operator and equipment. It causes the saw teeth to break and cracks.
Plug the machine's electrical power socket into the previously prepared 3-phase socket socket to follow the
saw-turn direction and follow the following procedures
:
1.
Press the motor start button to rotate the saw
.
2.
Observe the direction of rotation of the saw
.
3.
The direction of rotation of the saw is available on the turn direction label on the table
.
If the saw blade rotates in reverse direction: The electric socket connections have to be checked and
corrected by a qualified electrician. The direction of rotation of the saw must not be run without testing.
5.3. Air Pressure Setting
For the pneumatic system to operate properly, the air pressure must be 6-8 bars.
Do not operate at lower
pressures than 6 bars.
Read the manometer on the conditioner to calibrate and check the air pressure.
Follow the steps below for air pressure settings.
5.3.1.Pull up the conditioner adjustment knob.
5.3.2.The pressure increases when the knob is turned clockwise, while the pressure decreases when it is turned
counter-
clockwise.
5.3.3.When you read the 6-8 Bar pressure setting on the pressure gauge, lock the conditioner setting knob.
5.3.4.
The conditioner unit accumulates the water contained in the air system into the collection container so
as not to damage the pneumatic system components. Automatically removes water collected when air
is supplied to the machine.
5.3.5.The oil recommended by the manufacturer in the conditioner is TELLUS C 10 / BP ENERGOL HLP 10 /
MOBIL DTE LIGHT / PETROL OFFICE SPINDURA 10.
6. MACHINE SAFETY DATA
6.6.1.
It is not allowed to operate the machine with the protective cover and other
protective equipment removed.
6.6.2.
Your machine must be operated with the voltage on the technical label. Let the
electric installation of your machine carry out by a qualified electrician only.
Grounding must be done. There will be irregularities in machine operation if
grounding is not done properly.
6.6.3.
Lifting, installation, electric, pneumatic maintenance of the machine should be
carried out by qualified personnel only.
13