background image

 

 
 
  

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Housing 

 

Dimensions 

96 x 48 x 88 mm 

Display 

Single Line , 6 Digits 14mm LED Display ( RED color ) 

Display Range 

-99999….999999 

Weight 

300 gram 

Box 

Suitable for flush-panel mounting 

Relative Humidity 

80% up to 31°C decreasing linearly 50% at 40°C. 

Operating Temperature 

0...50 ° C 

Storage Temperature 

-10...60 ° C 

Protection Class 

IP 60 front panel, IP 20 rear panel 

Electrical Characteristics 

 

Power Supply 

24V AC/DC 50/60 Hz.or  85-265 VAC 50/60 Hz.

 

Power Consumption 

Max. 5,5VA -  4.4 W 

Connections 

2,5 mm²  screw-terminals connection 

Inputs 

 

Counting Frequency 

600 KHz (Quadrature mode)  

Input Channels 

A, B counting inputs; Z  external reset input; external HOLD input 

Z (Reset Input) 

Selectable in Rise or Fall edge triggering  (From software) 

HOLD Input 

Selectable in Rise or Fall edge triggering  (From software) 

Polarity Input 

Programmable, npn or pnp for all inputs 

Outputs 

 

Control Ouutput 

4 Relay: 250 VAC, 3 A (for Resistive load) COM, NO and NC 

Sensor Supply Output 

5 VDC or 12 VDC,  100 mA  

Digital Out 

RS-232 Serial Interface 

 

WARNINGS 

 
 
 
 
 
 
 
 

 

94x48 mm dimensions 

 

600 KHz reading speed 

 

6 digit display 

 

Functional External Z input 

 

Functional  HOLD input 

 

Quadrature mode up – down counting 

 

2 or 4 couple contact relay output 

 

Set-1 can be set related with Set 2  

 

Optional factor value (between 0,00001 and 999999) 

 

Optional decimal point  between 1. and 5. digits  

 

5 VDC or 12 VDC encoder power supply 

 

11 various output control mode 

 

OFFSET value is adjustable 

 

Password Protection

 

 

1. Fallow the instructions and read the manuel before conection and using the device.  
2. Check the power supply type before giving energy. 
3. Mount the device to the panel robustly againts to the drops, vibration and shakings during utilization. 
4. Make the sensor connections while the energy off. Never change the connections while the energy is on. 
5. Keep Away from the high voltage. 
6. Don’t expose to the sunbeams and heating source directly in the utilization place. 
7. ALC94 Industrial Control Device proper only for room conditions, don’t use outer environment. 
8. Clean the device only with a moist duster, never use water, thinner ect... 
9. Adapt the relays to the given technical relay output values. 
10. There is no part for replacing or repairing, please call the service in case a defect. 

 

HIGH SPEED UP / DOWN COUNTER

 

ALC94  

 

      

 

Summary of Contents for ALC-94 Series

Page 1: ...ns 600 KHz reading speed 6 digit display Functional External Z input Functional HOLD input Quadrature mode up down counting 2 or 4 couple contact relay output Set 1 can be set related with Set 2 Optional factor value between 0 00001 and 999999 Optional decimal point between 1 and 5 digits 5 VDC or 12 VDC encoder power supply 11 various output control mode OFFSET value is adjustable Password Protec...

Page 2: ...ED Signs by Out 1 output relay gets power 7 Out 2 output condition LED Signs by Out 2 output relay gets power 8 Out 3 output condition LED Signs by Out 3 output relay gets power Optional 9 Out 4 output condition LED Signs by Out 4 output relay gets power Optional ALC 94 Series FRONT PANEL DESCRIPTION FRONT PANEL USAGE Entering the value to numerical parameters Press RST and enter the programme the...

Page 3: ...3 SOCKET CONNECTION ALC 94 Series DIMENSION and PANEL CUT OUT Panel cut out ...

Page 4: ...esent SET value on the display When you press to PRG button again the last digit will flashing You can set the intended value by using UP DOWN buttons To pass to other digit press LEFT button The digit will pass left for each LEFT button pressing To change the point place POINT menu is used This subject will descripe in POINT MENU After presetting the intended value press PRG to save the value If ...

Page 5: ... point the accuracy of the value can be selected Also the SET and HYSTERESYS manus poing place can be adjust by this command To adjust the point menu press and hold PRG button and press to RST button POINT menu can be found by UP DOWN buttons In POINT Menu when you press to PRG button you can see the setted point possition Press to PRG button and the value will be flashing By Up Down buttons you c...

Page 6: ...enu Press Prg again to make flashing the options If you press to yes option the device asks you the password The password sets by UP Down buttons and use LEFT button to pass to other digits Press Prg to save the return to the factory settings Restoring Factory Settings Fac def Factory menu used for restoring factory settings All the settings will be changed by this menu So it will be beneficial to...

Page 7: ...f the decrease down the Set values the Outputs don t turn off Only if the RESET comes the outputs turns off When the counting value reachs to Set 1 value Out 1 turn ON and also reachs Set 2 value Out 2 turn ON Out 1 and Out 2 keeps on state in following condition Counting Value Set 1 Counting Value Set 2 NOTE It must be following conditins for all Output modes OFFSET SET 1 SET 2 OUTPUTS ALC 94 Ser...

Page 8: ...epend on the OUT 2 It should be enter the TOUT 2 is time and the TOUT 1 is HOLD Namely when the counting value reachs to Set 1 the OUT 1 turn on and if decrease under to Set 1 it s turn off When the counting value reachs to Set 2 the OUT 2 turn on and the counting value is held The counting value and outputs will be auto reseted in the end of the TOUT 2 time It is also Autoreset mode same as Outpu...

Page 9: ...e reachs to Set 1 the OUT 1 turn on and if it decrease under the Set 1 OUT 1 turns off When the counting value reachs to Set 2 the OUT 2 turn on Even if the decrease down the Set values Out 2 doesn t turn off unless the counting value reach to OFFEST value If the RESET comes the outputs turns off The OUT 1 keeps on until the counting value reachs to SET 1 When the counting value reachs to SET 1 OU...

Page 10: ... If the RESET comes the outputs turns off In this mode it should be selected the TOUT parameters as HOLD The OUT 1 keeps on until the counting value reachs to SET 2 When the counting value reachs to SET 2 OUT 1 turns off and OUT 2 turns on When the counting value increase and reaches reachs to Set 1 OUT 2 turns off and OUT 1 turns on If the RESET comes the counting value becomes the Offset ALC 94 ...

Page 11: ...ensor com ALC77 RS 232 parameters are as follows There is setting on the devices Is one way communications device to the receiving terminal Data format RS232 EOL 16bit data EOL End of line character Baud rate 57600 bps Data bits 8 Stop bits 1 Parity none DATA PROTOCOL ALC 94 Series ERROR MESSAGES If the value is very high 999999 is written If the value is very low 999999 is written ...