8
Output-3:
Output-4:
Output-5:
When the counting value reachs to Set-1, the OUT-1
turn on and if decrease under to Set-1 it’s turn off.
When the counting value reachs to Set-2, the OUT-2
turn on and the counting value is held (namely it
doesn’t count).
If the RESET comes, the outputs turns off.
It is Autoreset mode. In this mode OUT-1 depend on
the OUT-2. It should be enter the TOUT-2 is time and
the TOUT-1 is HOLD. Namely, when the counting value
reachs to Set-1, the OUT-1 turn on and if decrease
under to Set-1 it’s turn off. When the counting value
reachs to Set-2, the OUT-2 turn on and the counting
value is held.
The counting value and outputs will be auto-reseted in
the end of the TOUT-2 time.
It is also Autoreset mode same as Output-4
The difference is the counting value isn’t held, namely
after reached to Set-2, the instrument continue to
count.
ALC-94 Series