KN9008 / KN9016 User Manual
34
F4: ADM
F4 is an administrator only function. It allows the administrator to configure
and control the overall operation of the OSD. To change a setting double-click
it, or use the up and down arrow keys to move the highlight bar to it then press
[Enter]
.
After you select an item, a submenu with further choices to select from appears.
Double-click an item, or move the highlight bar to it then press
[Enter]
. An
icon appears before the selected item so that you know which one it is. The
settings are explained in the following table:
Setting
Function
SET IP
ADDRESS
This entry allows you to select whether to assign the KN9008 /
KN9016’s IP address dynamically (DHCP), or to give it a fixed IP
address. Press
[Space]
to toggle between the choices.
If you toggle
DHCP Enable
to Off, specify the IP, Mask, and
Gateway in the appropriate fields. (Methods to determine the
KN9008 / KN9016's IP address are described in the Appendix on
page 145.)
Press
[Esc]
to exit after you have finished with your choice.
SET LOGOUT
TIMEOUT
If there is no input from the console for the amount of time set with
this function, the Operator is automatically logged out. A login is
necessary before the console can be used again.
This enables other Operators to gain access to the computers
when the original Operator is no longer accessing them, but has
forgotten to log out. To set the timeout value, key in a number from
0–180 minutes, then press [Enter]. If the number is 0 (zero), this
function is disabled. Default is 0 (disabled).
EDIT PORT
NAMES
To help remember which computer is attached to a particular port,
every port can be given a name. This function allows the
administrator to create, modify, or delete port names.
To edit a port name:
1. Click the port, or use the navigation keys to move the highlight
bar to it, then press
[Enter]
.
2. Key in the new port name, or modify/delete the old one. The
maximum number of characters allowed for the port name is 12.
Legal characters include:
All alpha characters:
A
–
Z
All numeric characters:
0
–
9
-
and
Space
Case does not matter; OSD displays the port name in all
capitals no matter how they were keyed in.
3. When you have finished editing, press
[Enter]
to have the
change take effect. To abort the change, press
[Esc]
.
Summary of Contents for Altusen KN9008
Page 1: ...KVM Over the NET KN9008 KN9016 User Manual www aten com ...
Page 14: ...KN9008 KN9016 User Manual xiv This Page Intentionally Left Blank ...
Page 24: ...KN9008 KN9016 User Manual 10 Rear Panel KN9008 KN9016 1 2 3 4 5 6 7 1 2 6 7 3 4 5 ...
Page 26: ...KN9008 KN9016 User Manual 12 This Page Intentionally Left Blank ...
Page 62: ...KN9008 KN9016 User Manual 48 This Page Intentionally Left Blank ...
Page 88: ...KN9008 KN9016 User Manual 74 This Page Intentionally Left Blank ...
Page 120: ...KN9008 KN9016 User Manual 106 This Page Intentionally Left Blank ...
Page 124: ...KN9008 KN9016 User Manual 110 This Page Intentionally Left Blank ...
Page 126: ...KN9008 KN9016 User Manual 112 This Page Intentionally Left Blank ...
Page 142: ...KN9008 KN9016 User Manual 128 This Page Intentionally Left Blank ...
Page 174: ...KN9008 KN9016 User Manual 160 This Page Intentionally Left Blank ...