w
F2 Scan:
Pressing [F2] initiates Quick View Scanning, in which the OSD cycles
through all the ports that are currently selected in the List view (see F3,
below), and displays each one for the amount of time specified with the Set
Scan Duration setting under the F6 SET function (see p. 20). When you
want to stop at a particular location, press the [Spacebar] to stop scanning.
Note: 1. If the scanning stops on an empty port, or one where the computer
is attached but is powered Off, the monitor screen will be blank,
and the mouse and keyboard will have no effect. To recover, key
in the Hotkey sequence (see OSD Hotkey Navigation, p. 16), for
any Port ID that has an active computer attached.
2. As each computer is accessed, an
appears in front of the Port
ID display to indicate that it is being accessed under Quick View
Scan Mode.
w
F3 List:
This function lets you broaden or narrow the scope of which ports the OSD
lists. The submenu choices and their meanings are given in the table, below:
Choice
Meaning
ALL
Lists the Port ID numbers and Names (if names have been
specified - see F5, below), of all the ports on the installation.
QVIEW
Lists only the ports that have been selected for Quick View
scanning (see F4, below).
POWERED ON +
QVIEW
Lists only the ports that have been selected for Quick View
scanning (see F4, below), and that have their attached
computers Powered On.
QVIEW + NAME
Lists only the ports that have been selected for Quick View
scanning (see F4, below), and have been assigned names
(see F5, below).
NAME
Lists only the ports that have been assigned names (see F5,
below).
POWERED ON
Lists only the ports that have their attached computers
Powered On.