background image

Sheet # 692/1u – 

Electric connectors (F610)

 

Version 1.04a 

User guide 

ATEQ 6th series

 Page 6/7 

4.2.1. 2)  PLC in PNP mode connection 

I

1

 (Reset) 

Customer

Inputs board 

16/32 programs 

I

2

 (Start) 

I

3

 (Pr 1 + 1) 

I

4

 (Pr 2 + 1) 

Good part 

Common 

Test fail part 

Reference fail part 

Alarm 

End of cycle 

24 V DC 

24 V DC 

ATEQ or customer

I

6

 (Pr 8 + 1) 

I

5

 (Pr 4 + 1) 

I

7

 (Programmable input) 

16 

15 

14 

13 

12 

11 

10 

PNP MODE 

Ground 

+ 24 V DC

J3 

IN

PUT

S

 

OUT

P

UT

OUTPUTS

 

 

 

 

 

 

 

INPUTS

Customer 

0 V 

(0,3 A max) 

Note

: The 24V power supply must be 

provided by the internal power supply 
of the ATEQ instrument (0,3A 
maximum) 

OR

 through an external 

power supply provided by the 
customer. 

In the case of customer external 
supply, the ATEQ instrument can be 
supply by the 2 and 4 pins on the J3 
connector too.

 

4.2.1. 3)  Lights connection 

I

1

 (Reset) 

Customer

Inputs board 

16/32 programs 

I

2

 (Start) 

I

3

 (Pr 1 + 1) 

I

4

 (Pr 2 + 1) 

Good part 

Common 

Test fail part 

Reference fail part 

Alarm 

End of cycle 

24 V DC 

I

6

 (Pr 8 + 1) 

I

5

 (Pr 4 + 1) 

I

7

 (Programmable input) 

16 

15 

14 

13 

12 

11 

10 

Ground 

+ 24 V DC

J3 

IN

P

U

T

S

 

OUTP

UTS 

OUTPUTS

0,3 A Max 

with ATEQ 

24 V DC 

!

0,2 A 

Max 

0,2 A 

Max 

(0,3 A max) 

Note

: The 24V power supply must be 

provided by the internal power supply 
of the ATEQ instrument (0,3A 
maximum) 

OR

 through an external 

power supply provided by the 
customer. 
In the case of customer external 
supply, the ATEQ instrument can be 
supply by the 2 and 4 pins on the J3 
connector too. 

Summary of Contents for 6th series

Page 1: ...s are located under the rubber cover USB connector to plug a PC USB connector to plug an UBS memory key or a remote control The USB connector rubber cover can be slightly deviated to the front for easy access to connectors Do not plug two USB components together 2 LOWER SIDE CONNECTORS Example of lower side face Note following the versions and the purchase options the customer device may be differ...

Page 2: ...V on the pin 16 See the paragraph 4 2 Connector I O all or nothing 3 2 RS232 CONNECTOR PRINTER MODBUS OR PROFIBUS 3 2 1 Connector in RS232 mode 1 5 9 6 RS232 SubD 9 points male connector To plug a printer a bar code reader a PC a save module Pin 1 Not used Pin 4 Not used Pin 7 RTS request to send Pin 2 RXD data input Pin 5 Earth Ground Pin 8 CTS clear to send Pin 3 TXD data output Pin 6 Not used P...

Page 3: ...3 DEVICENET PROFINET OR ETHERNET CONNECTORS OPTION 3 3 1 Devicenet Input option 2 1 4 3 5 To connect to others ATEQ devices M12 male connector 3 3 2 J2 Devicenet output option 2 1 4 3 5 To connect to others ATEQ devices M12 female connector 3 3 3 Wiring Devicenet Pin 1 Drain Pin 3 V Pin 5 CAN_L Pin 2 V Pin 4 CAN_H 3 3 4 Input and output Profinet 4 3 1 2 5 Ethernet M12 pin assignement M12 female D ...

Page 4: ...OPTION 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 Output inputs codes Pin 1 COMMUN Outputs 1 2 3 24 V DC Pin 2 Output n 1 open collector Pin 3 Output n 2 open collector Pin 4 Output n 3 open collector Pin 5 COMMON Outputs 4 5 6 24 V DC Pin 6 Output n 4 open collector Pin 7 Output n 5 open collector Pin 8 Output n 6 open collector Output codes 24V DC 100mA Max Pin 9 Input 0 NPN or PNP Pin 10 Input 1 NPN...

Page 5: ...eference part Output 3 Pass part cycle 2 14 Output 4 Alarm Output 4 Fail part cycle 2 Alarm 15 Output 5 End of cycle Output 5 End of cycle 16 0 V 0 V Outputs dry contacts 60V AC DC Max 200mA Max The compact mode is a software function which is activated in the CONFIGURATION AUTOMATISM CHANGE I O OUTPUT menu 4 2 1 Connector I O Inputs Outputs graphical representation 4 2 1 1 PLC in NPN mode connect...

Page 6: ...er supply provided by the customer In the case of customer external supply the ATEQ instrument can be supply by the 2 and 4 pins on the J3 connector too 4 2 1 3 Lights connection I1 Reset Customer Inputs board 16 32 programs I2 Start I3 Pr 1 1 I4 Pr 2 1 Good part Common Test fail part Reference fail part Alarm End of cycle 24 V DC I6 Pr 8 1 I5 Pr 4 1 I7 Programmable input 16 15 14 13 12 11 10 9 8 ...

Page 7: ...V 0 3 A maximum Combinations of pins to activate to select programs Program number I Oconn Pin 5 input 3 I O Conn Pin 6 input 4 I O Conn Pin 7 input 5 I O Conn Pin 8 input 6 I O Conn Pin 9 input 7 Extens Pin 1 input 8 Extens Pin 2 input 9 1 0 0 0 0 0 0 0 2 1 0 0 0 0 0 0 3 0 1 0 0 0 0 0 4 1 1 0 0 0 0 0 5 0 0 1 0 0 0 0 6 1 0 1 0 0 0 0 7 0 1 1 0 0 0 0 8 1 1 1 0 0 0 0 9 0 0 0 1 0 0 0 10 1 0 0 1 0 0 0 ...

Reviews: