Quick start manual -
F5200
MR-F5200B-U
Quick start manual
ATEQ F5200
Page 5/17
2.4.
J1
C
ONNECTOR
O
UTPUT CODES
/
A
NALOGUES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Output codes / Analog
outputs / temperature sensor.
PIN 1
COMMON (outputs 1, 2, 3) + 24 V DC
PIN 2
Output n°1, open collector
PIN 3
Output n°2, open collector
PIN 4
Output n°3, open collector
PIN 5
COMMON (outputs 4, 5, 6) + 24 V DC
PIN 6
Output n°4, open collector
PIN 7
Output n°5, open collector
PIN 8
Output n°6, open collector
OUTPUT
CODES
24V DC
100mA Max
Outputs
PIN 9
12V Sensor power supply
PIN 10
0V Sensor power supply
PIN 11
SENSOR n°1 input
PIN 12
SENSOR n°2 input
TEMP°
SENSORS
PIN 13
Analogue outputs n°1
PIN 14
COMMON (analogue output 1)
PIN 15
Analogue output n°2
PIN 16
COMMON (analogue output 2)
ANALOGUE
OUTPUTS
24 V DC
8
7
6
5
4
3
2
1
0,1 A max
Charge / Load
Obligatory
diode for an
inductive load.
2.5. J3
C
ONNECTOR
I/O
ALL OR NOTHING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Inputs / All or nothing outputs.
Pin
Standard mode
Compact mode
1
Input 1 Reset
Input 1 Reset
2
Common (+ 24 V)
Common (+ 24 V)
3
Input 2 START
Input 2 START
4
Common (+ 24 V)
Common (+ 24 V)
5
Input 3 Program selection
Input 3 Program selection
6
Input 4 Program selection
Input 4 Program selection
7
Input 5 Program selection
Input 5 Program selection
8
Input 6 Program selection
Input 6 Program selection
9
Input 7 Program selection
Input 7 Program selection
INPUTS
(Activating by
24 V DC)
Common
+ 24 V = 0,3 A
maxi
10
Floating common output
Floating common output
11
Output 1 Pass part
Output 1Pass part cycle 1
12
Output 2 Test error
Output 2 Fail part cycle 1 + alarm
13
Output 3 Reference error
Output 3 Pass part cycle 2
14
Output 4 Alarm
Output 2 Fail part cycle 2 + alarm
15
Output 5 End of cycle
Output 5 End of cycle
16
0 V
0 V
DRY CONTACT
OUTPUTS
60V AC / DC Max
200mA Max
The compact mode is a software function which is activated in the
CONFIGURATION /
CHANGE I/O / OUTPUT
menu.
2.5.1. J3 Connector program selection
The various test programs can be selected individually depending on the inputs
combination of this connector.
Summary of Contents for F5200
Page 1: ...QUICK START MANUAL ATEQ F5200 Version 1 01 Photo no contractual Reference MR F5200B U...
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......