FG_F6_MODBUS_EN_01 / 2020-06-17
34 / 74
Word
Bit n°
Mask
D.A. address
Meaning
Menu
Hexa
Dec
Read
Write
5
64
0001
1
264F
664F
Start after reading bar code function.
Funct
65
0002
2
260E
660E
ATR3 function.
Funct
66
0004
4
266B
666B
Absolute value function.
Funct
67
0008
8
266C
666C
Bypass valve function.
Funct
68
0010
16
Reserved.
69
0020
32
266F
666F
Inverted sealed component function.
Funct
70
0040
64
2670
6670
Inverted sealed component 2 function.
Funct
71
0080
128
2671
6671
Dump off function.
Funct
72
0100
256
2672
6672
Cut off function.
Funct
73
0200
512
2673
6673
ATF function.
Funct
74
0400
1024
2674
6674
Asynchrony fill between bell and part in
recovery or indirect mode.
Funct
75>79
Reserved.
6
80>95
Word Reserved.
7
96
0001
1
267D
667D
Optional auxiliaries codes function.
Funct
97
0002
2
267E
667E
Optional auxiliaries codes 1 function.
Funct
98
0004
4
267F
667F
Optional auxiliaries codes 2 function.
Funct
99
0008
8
2680
6680
Optional auxiliaries codes 3function.
Funct
100
0010
16
2681
6681
Optional auxiliaries codes 4 function.
Funct
101
0020
32
2682
6682
Optional valves codes function.
Funct
102
0040
64
2683
6683
Optional external valves codes 1.
Funct
103
0080
128
2684
6684
Optional external valves codes 2.
Funct
104
0100
256
2685
6685
Optional external valves codes 3.
Funct
105
0200
512
2686
6686
Optional external valves codes 4.
Funct
106
0400
1024
2687
6687
Optional external valves codes 5.
Funct
107
0800
2048
2688
6688
Optional external valves codes 6.
Funct
108
1000
4096
2689
6689
Optional internal valves codes 1.
Funct
109
2000
8192
268A
668A
Optional internal valves codes 2.
Funct
110
4000
16384
268B
668B
Buzzer function.
Funct
111
8000
32768
268C
668C
Pass part buzzer function.
Funct
8
112
0001
1
268D
668D
Fail part buzzer function.
Funct
113
0002
2
268E
668E
Alarm buzzer function.
Funct
114
0004
4
268F
668F
End of cycle buzzer function.
Funct
115
0008
8
2694
6694
Long Test Time function.
Funct
116
0010
16
2691
6691
Permanent dump function.
Funct
117
0020
32
2692
6692
Input 7 test function.
Funct
118
0040
64
2693
6693
Burst test function (results are inverted).
Funct
119
0080
128
2698
6698
Sealed Diff components function.
Funct
120
0100
256
2699
6699
Test or Ref Mode function.
Funct
121
0200
512
26AE
66AE
Pressure Drop.
Funct
122
0400
1024
26AF
66AF
Auto Verif Etal.
Funct
123
0800
2048
26B0
66B0
Pressure correction (≥v1.400)
.
Funct
124
1000
4096
2675
6675
Standard conditions (≥v1.400)
.
Funct
125
2000
8192
26B1
66B1
Ref No Dump.
Funct
126
4000
16384
26B2
66B2
Offset.
Funct
127
8000
32768
26B3
66B3
Permanent Fill.
Funct