The installation in a saline environment must be done with isolators to prevent galvanic
corrosion between the module and the support structure.
When solar modules are connected in series,
they must all face the same direction and have
the same angle of inclination. There must also
be a proper gap (minimum 30cm) between
the module and the surface for ventilation
purposes.
(2)
The ATERSA modules design allows the correct
evacuation of water. They have open edges in
the inside tube.
The modules must be installed on independent fixed structures. The structure must not
transmit stress to the modules.
The longest side of the aluminium frame has a series of 6,7mm diameter drill holes.
Use M6 stainless steel screws to install it on the structure and the proper torque
values should be between 6 to 8Nm. The following screw system should be
employe
.
.
5.- INSTALLATION
5.1.- Mechanical Installation
5.1.1.-Directly on the Structure
d (3)
IMPORTANT:
NOT
Do
install the modules
with the junction box in the lower side. View
image
RECOMMENDED
2
NO
* Nota:
Use M6 DIN 9021 washer for Hook V4 profile.
Use M6 DIN 125 washer for Hook V1 profile.
M6 WASHER
M6 GROWER WASHER
M6 SCREW
3
FRAME
M6 NUT
STRUCTURE
*M6 WASHER
3
‘
MODULE
Installation and User Manual
EN-MU-41 (4)-E