CAUTION
- The unplugging of the battery with the panel and/or connected consumption can
cause grave damages to the equipment. As a standard we consider the following:
THE BATTERY IS THE FIRST TO BE CONNECTED AND THE LAST TO BE
UNPLUGGED.
- BEFORE MAKING EACH CONNECTION IT IS IMPORTANT TO CHECK THE
POLARITY. When you handle the panels connections, it is important to avoid a
possible short-circuit between the positive and negative of the panels line, as it
implies a short-circuit in the battery through the regulator. That would cause serious
damages to the equipment if there is no option of blocking diode.
- The installation of the equipment is usually made near to the accumulators. The
gases emitted are explosive when they reach a certain concentration, that is why it is
important that the place feature a correct ventilation and not to cause sparking nor
flames.
- The regulator works (open/close) on the negative lines when it makes the control.
The positive lines are common (panels, battery, consumption). If you want to make a
ground connection of the installation, you must take into account this circumstance,
and in any moment refer to the Electro-technical Regulation on Low Voltage
Photovoltaic
Modules Input
Consumption
Output
Indicator charge phase
Indicator floating phase
Indicator consumption unplugging
Indicator high voltage in batteries alarm
Indicator low voltage in batteries alarm
Fixing
drill
Fixing
drill
Push-button consumption
Push-button battery voltage
Push-button charge intensity
Connections
Reglet
290 mm
135mm
272 mm
L
E
O
1
2
3
4
5
A
A
V
L
E
O
+
-
+
-
+
-
Display
Batteries
E
N
G
L
I
S
H
07
DIGITAL CHARGE REGULATOR
LEO1
MU-12-L