OPTIMUM GS MODULES INSTALLATION MANUAL

                                                                     

 

Page 21 

Aplicaciones Técnicas de la Energía S.L. (ATERSA) 

www.atersa.com – atersa@elecnor.com   

Madrid (Spain) +34 915 178 452 - Valencia (Spain) +34 961 038 430 

 

Module 

A-xxxM GS (for 60 cells 6”). 

where xxx = 235~270 in step of 5 W.. 

Max. power    (W) 

235 

240 

245 

250 

255 

260 

265 

270 

Open-circuit voltage (V) 

37,70 

37,77 

37,86 

38.00 

38,10 

38,20 

38,31 

38,42 

Max. power point voltage    (V) 

29,38 

29,86 

30,21 

30,49 

30,92 

31,18 

31,48 

31,73 

Short-circuit current    (A) 

8,59 

8,64 

8,70 

8,78 

8,84 

8,92 

8,99 

9,08 

Max. power point current    (A) 

8,00 

8,04 

8,11 

8,20 

8,25 

8,34 

8,42 

8,51 

Efficiency (%) 

14,4 

14,8 

15,1 

15,4 

15,7 

16,0 

16,3 

16,6 

*

Notes

 

      Maximum System Voltage                              1000V 

      Nominal Operating Cell Temp (NOCT)          46±2

ºC 

      Temperature Cycling Range                          -40 ºC to +85

 ºC

 

      Class C fire rating 

 

Storage temperature:                             

-40°C to +40°C, 

 

Wind pressure:                                   

 

below 2400Pa 

    Humidity:                                              

 

below 85RH% 

      The modules are qualified for application class A: Hazardous voltage (IEC 61730: higher 

than 50V DC; EN 61730: higher than 120V), hazardous power applications (higher than 240W) 

where  general  contact  access  is  anticipated  (Modules  qualified  for  safety  through  EN  IEC 

61730-1  and  -2  within  this  application  class  are  considered  to  meet  the  requirements  for 

Safety Class II).

 

 

Summary of Contents for OPTIMUM A-235P GS

Page 1: ...ATION MANUAL Page 1 Aplicaciones T cnicas de la Energ a S L ATERSA www atersa com atersa elecnor com Madrid Spain 34 915 178 452 Valencia Spain 34 961 038 430 OPTIMUM GS Modules Installation Manual Re...

Page 2: ...ty 4 Precaution for unpacking handling storage 5 Warning 6 Installation 6 1 Mechanical Installation 6 1 1 Bolting method 6 1 2 Clamping method 6 2 Electrical Connections 6 2 1 Equipment Grounding 6 2...

Page 3: ...f or in any way connected with such installation operation use or maintenance No responsibility is assumed by Atersa for any infringement of patents or other rights of third parties which may result f...

Page 4: ...shall comply with national regional and local codes laws and standards PV modules should be installed and maintained by qualified personnel Only installation service personnel should have access to t...

Page 5: ...s to avoid injury by a slipping module cuts by the edge of a frame etc Do not leave the module unsupported or unsecured prior to installation For example wind can cause a module which is leaning again...

Page 6: ...lation of PV modules Use module for its intended function only Be sure that all other system components are compatible and they do not subject the module to mechanical or electrical hazards Do not tou...

Page 7: ...the southern hemisphere The assembly is to be mounted over a fire resistant roof covering rated for the application The roof slope should be less than 5 in ft less than 22 62 to maintain fire class r...

Page 8: ...not accessible to children or small animals to ensure personal safety and to prevent PV module from damage The junction box shall be in the uppermost position to minimize the ingress of water Clearan...

Page 9: ...oints The hardware required to mount the module is given below Stainless steel M8 304 bolt Stainless steel M8 304 washer Stainless steel M8 304 nut We recommend using a torque wrench for installation...

Page 10: ...lecnor com Madrid Spain 34 915 178 452 Valencia Spain 34 961 038 430 6 1 2 Clamping method For the clamping method is recommended use clamps with figure s sizes The hardware used is the same as boltin...

Page 11: ...OPTIMUM GS MODULES INSTALLATION MANUAL Page 11 Aplicaciones T cnicas de la Energ a S L ATERSA www atersa com atersa elecnor com Madrid Spain 34 915 178 452 Valencia Spain 34 961 038 430...

Page 12: ...OPTIMUM GS MODULES INSTALLATION MANUAL Page 12 Aplicaciones T cnicas de la Energ a S L ATERSA www atersa com atersa elecnor com Madrid Spain 34 915 178 452 Valencia Spain 34 961 038 430...

Page 13: ...mm grounding holes 5 1mm to ground the anodized frame 10 12 AWG exposed copper wire is recommended as Ground wire The fastening system must be spliced with a cable that has a minimum diameter of 2 5m...

Page 14: ...ed in series with each module or string of modules Match the polarities of cables and terminals when making the connections failure to do so may result in damage to the module Connecting modules in re...

Page 15: ...or the corresponding equipment to which the module are connected A cable with an adequate section for the conduction of the total current generated by the modules should be used In all case the conduc...

Page 16: ...Always wear rubber gloves for electrical insulation while maintaining washing or cleaning modules Appropriate electrically insulating Personal Protective Equipment PPE must be worn during any cleaning...

Page 17: ...permanent damage to the glass such as white efflorescence otherwise known as glass disease which may cause reduced power output To avoid dirt accumulation or white efflorescence due to water accumulat...

Page 18: ...rsa com atersa elecnor com Madrid Spain 34 915 178 452 Valencia Spain 34 961 038 430 9 Checklists All fastenings are tight and secure and free of corrosion All cable connections are secure tight clean...

Page 19: ...STC Irradiance of 1000 W m2 AM1 5 spectrum and a cell temperature of 25 C The tolerance of Electrical Characteristics is less than 10 under Standard Test Conditions 2 1 Polycrystalline module Module A...

Page 20: ...ort circuit current A 8 54 8 71 8 84 8 90 8 97 9 05 9 10 9 13 Max power point current A 8 04 8 17 8 28 8 35 8 42 8 49 8 56 8 04 Efficiency 14 5 14 8 15 1 15 4 15 7 16 0 16 3 14 5 2 2 Monocrystalline m...

Page 21: ...9 08 Max power point current A 8 00 8 04 8 11 8 20 8 25 8 34 8 42 8 51 Efficiency 14 4 14 8 15 1 15 4 15 7 16 0 16 3 16 6 Notes Maximum System Voltage 1000V Nominal Operating Cell Temp NOCT 46 2 C Te...

Reviews: