Soldering iron tip maintenance
1. Set the temperature to 250
℃
(480
℉
).
2. After the temperature is stable, clean the soldering iron tip with a brass wool and check its condition.
3. If black oxide is attached to it, please apply new solder (including flux) and wipe it repeatedly with a brass wool
until it’s clean, then apply some new solder.
4. If the soldering iron tip has been deformed, perforated or worn out, please replace it with a new one.
Not working after
power is on
The display shows "S-E"
The display shows "H-E"
Iron tip heating is on
and off
The solder won’t get on
the iron tip
Iron tip temperature is
too low
The iron tip won’t fit
The actual temperature
can’t reach
Check whether the power
cord is good, or plug falls off
Is the fuse OK
Whether the handle cable is well
connected with main unit
Whether the heater is damaged
(the resistance of the blue lead wire
shall be less than 100 Ω at room
temperature).
If damaged, replace the heater
Whether the heater is damaged
(the resistance of the red lead wire
shall be less than 100 Ω at room
temperature)
If damaged, replace the heater
Reconnected
Whether the wire connecting to
handle is broken
If so please replace it with a new handle
Whether the wire connecting to
handle is broken
If so please replace it with a new handle
Whether the wire connecting to
handle is broken
Check whether the temperature of
the iron tip is too high
Whether the temperature is proper
Is the temperature adjusted correctly
Haven’t done temperature calibration
for a long time
Adjust the set temperature again
Re-calibrate temperature accordingly
Whether there is oxide inside tip, or
soldering iron tip expands
Not original tip or not same type tip
Change the tip and heater
use original factory tip or same type tips
Adjust to the proper temperature
Adjust to the proper temperature
Check whether there is oxide on
the tip
Check whether there is oxide on
the tip
Clean the oxide with a brass wool
Clean the oxide with a brass wool
If so please replace it with a new handle
Connect the power supply well
Figure out the cause of fuse damage:
1. Short circuit inside the station.
2. Inside the handle, the spring might meets the
heating element.
3. Check whether the pin of heating element is
twisted or short circuited.
Even if the cause is unknown, please replace the
fuse. If the fuse get burnt out again, please return
the handle with the main unit for maintenance.
After the power is on, indicator lights up, and the soldering station starts heating up according to the set
temperature. After the temperature is stable, indicator flashes.
Note: when not in use, please put the soldering iron on the holder. If it won’t used for a while, please cut off the
power supply.
1) Adjust the set temperature to 350
℃
(662
℉
) by knob and wait for 2 minutes to stabilize the temperature.
2) Use a thermometer to measure the temperature of the soldering iron tip.
3) Use a cross screwdriver to adjust the calibration hole to make the displayed temperature value equal to the
measured value. For example, if the measured value is 345
℃
, adjust calibration hole to reduce display
temperature 350 to 345, make the display temperature match the measured value.
4) Press the function key to complete calibration.
9.Temperature calibration
Using Method
(
AE988/AE970
)
Troubleshooting Guide
T900M series soldering tips(AE988/AE988D)
T80 series soldering tips(AE970/AE970D)
Maintenance
Warning
Please pay close attention when the soldering station is in use at high temperature, cut off the power
and unplug the power cord after use.
!
Indicator: indicate the power state
(light on/off means power on/off
)
Knob: adjust the temperature
Calibration hole: for calibrate the temperature
1.Operation and display instructions
2.Switch on the power
Temperature range: AE988/AE970
:
200-480
℃(
392-896
℉
).
Temperature adjusted by knob.
3.Temperature adjustment
1) Adjust the set temperature to 350
℃
(662
℉
) by knob and wait for 2 minutes to stabilize the temperature.
2) Use a thermometer to measure the temperature of the soldering iron tip.
3) Use a cross screwdriver to adjust calibration hole to make the measured value equal to set temperaure.
For example, if measured value is 345
℃,
adjust calibration hole to increase it to 350, make the measured
value match set temperature.
4) Temperature calibration completed.
4.Temperature calibration
In order to make this product durable, please maintain it regularly. The lifespan of this product depends on the
used temperature, quality of solder wire and soldering paste, frequency of use etc. Please repair and maintain
it according to specific use conditions.
Knob
Calibration hole
Indicator
socket
Warning
Failure
phenomenon
Examination
Dealing method
● When checking or replacing parts, be sure to pull out the power plug to prevent electric shock
● If the power cable is damage, it must be sent to the manufacturer, agency store or maintenance
personnel with the same qualification for repair to avoid accidents
!
4
5
6
T80-B2
900M-T-I
900M-T-B
900M-T-K
900M-T-1.2D
900M-T-1.6D
900M-T-2.4D
900M-T-3.2D
900M-T-4.6D
900M-T-6.5D
900M-T-0.8C
900M-T-6.4C
900M-T-3C
900M-T-5C
R0.5
10
T80-B2
R0.2
12
R0.2
7.5
T80-BL
R0.2
9.5
T80-I
T80-ILS
T80-B
R0.15
13.5
2
4.7
15
45°
T80-K
2.4
4.7
17
45°
T80-KF
1.5
4.7
11
45°
T80-KL
T80-KU
1.2
3
11
45°
R0.2
T80-J02
12
3.5
T80-BC1
11.5
1
T80-BC2
11.5
2
T80-BC3
10
3
T80-D08
9.5
0.8
0.5
T80-D12
10
1.2
0.5
T80-D16
10
1.6
0.5
T80-D24
10
2.4
0.5
Shenzhen ATETOOL Co., Ltd.
Address
:
F5, 1-2 #, Tongfuyu, Aiqun Road, Shiyan Street, Bao'an District, Shenzhen,
518132,P.R.China
Tel
:
(0755) 23408674 - 802
Support
:
(0755) 23408704 - 818
URL
:
www.atten.com.cn( in Chinese )
www.atten.com(in English)
(More soldering tips information please contact us)
(More soldering tips information please contact us)
CBN300123
(
A)
MADE IN CHINA