® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-11
Manufacturer ATH-Heinl GmbH & CO.KG
- 30 -
...and connect the cable to the middle
connection port on the machine.
2.9.7.
Activating the tyre width gauge
In order to access the system, you must press the key combination
shown opposite:
1.
First the C button and then the T button
2.
The CAL – CAL displays will appear and the indicator lights flash.
3.
Release the buttons only when the indicator light is steady.
4.
Press the A↓ button
5.
Press the A↑ button
6.
Press the ALU button
7.
Press the A↑ button four times
+
>
>
1x
Turn on/off the width gauge by using B↓; B↑
To end the process, press the A↑ button 4 times
4x