Troubleshooting
Error
Reason
Remedy
No display , machine
can not be switched-on
1. Power supply cable is not
well connected.
2. Fuse defect
3. LCD defect
1. Check power connection
2. Change the fuse
3. Change the LCD
Oil volume in the tanks
is not displayed
correctly
1. Load cells are not calibrated
correctly
2. Board or load cell do not
work correctly respectiveley are
not connected correctly.
1.Calibrate the load cells.
2. Check the connection, change the
board or load cell
Vibrations or big noise
Pump does not work correctly,
is not tightened correctly, the
cables are twisted or not
connected correctly.
Check the pump for tightness, check
cables.
Every function takes
excessively long
Defect on the cables
Check the system (cables, lines, solenoid
valves and control unit) for leakage.