- 20 -
15.
In the display appears [CAL]
–
[End]
16.
If [CAL]
–
[10] appears then the calibration is failed and must
be made again.
Calibration of piezo transducer in CAR mode
The machine
MUST BE
calibrated after the fixing and minimum before the season or after a longer
standstill.
Choose at first the CAR mode by pressing the MODEL button.
Clamp an already balanced wheel (14” or 15“) and input the
parameters (see Utilization, item 4).
For getting into the calibration system you must press the adjacent
key combination:
4.
First press the button C and then additional the button T
5.
Now appears in the display [CAL]
–
[CAL] and the indicators
are blinking
6.
Release the buttons only when the indicators are blinking
regular.
+
By pressing the button START or closing the protection bow the
balancing cycle for the calibration will be started.
After the balancing cycle appears the adjacent display.
Position the calibration weight (100g) on the INNER side of the rim.
/
By pressing the START button or closing the protection bow the
second balancing cycle for the calibration will be started.
After the balancing cycle appears the adjacent display.
Position the calibration weight (100g) on the OUTER side of the rim.
/
Press again the button START or close the protection bow for
finishing the calibration.
/