Setting the drive belt tension
1.
Carefully remove the cover (weight storage).
2.
Remove the fixing screws from the motor.
3.
Move the motor using a tensioning screw and ensure the correct belt tension is achieved when
doing so.
4.
Tighten the fixing screws on the motor again.
5.
Carry out a test run and ensure that the belt does not move to the side.
6.
Remount the cover.
Changing the fuses
1.
Carefully remove the cover (weight storage).
2.
Remove the fuse from the electricity supply board.
3.
Swap the old fuse for a new fuse, ensuring that the ratings of the fuses are the same.
If the problem persists, please contact the service team.
4.7
Élimination
Coupez l'alimentation en air et électrique.
Retirez toutes les substances non métalliques et conservez-les conformément aux prescriptions locales.
Vidangez l'huile de la machine et conservez-la conformément aux prescriptions locales.
Recyclez les substances métalliques.
La machine contient certaines substances nuisibles à l'environnement et qui peuvent causer
des blessures sur le corps humain si elles ne sont pas correctement traitées.
Summary of Contents for M126
Page 3: ...BEDIENUNGSANLEITUNG ATH M126 ...
Page 47: ...OPERATING INSTRUCTIONS ATH M126 ...
Page 91: ...MANUEL D UTILISATION ATH M126 ...
Page 135: ...NÁVOD K OBSLUZE ATH M126 ...
Page 179: ...MANUAL DE INSTRUCCIONES ATH M126 ...
Page 223: ...BEDIENINGSHANDLEIDING ATH M126 ...
Page 267: ...INSTRUKCJA OBŁSUGI ATH M126 ...
Page 311: ...NÁVOD NA OBSLUHU ATH M126 ...