Setting the drive belt tension
1.
Carefully remove the cover (weight storage).
2.
Remove the fixing screws from the motor.
3.
Move the motor using a tensioning screw and ensure the correct belt tension is achieved when
doing so.
4.
Tighten the fixing screws on the motor again.
5.
Carry out a test run and ensure that the belt does not move to the side.
6.
Remount the cover.
Changing the fuses
1.
Carefully remove the cover (weight storage).
2.
Remove the fuse from the electricity supply board.
3.
Swap the old fuse for a new fuse, ensuring that the ratings of the fuses are the same.
If the problem persists, please contact the service team.
4.7
Disposal
Remove the air and power supply.
Remove all non-metallic substances and store them in accordance with local regulations.
Remove the oil from the machine and store it in accordance with local regulations.
Recycle all metallic substances.
The machine contains some substances that can pollute the environment and cause harm
to the human body if not handled correctly.
Summary of Contents for W102