® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-10
Manufacturer ATH-Heinl GmbH & CO.KG
- 42 -
4.6
Maintenance and Service Instructions
All maintenance and service work should be carried out at least according to the
maintenance schedule
COMPRESSED AIR MAINTENANCE UNIT
(Partial stock if necessary for the activity)
SETTING THE WORKING PRESSURE:
Check the working pressure displayed by the
manometer (1). This must correspond to the
technical data.
The working pressure can be adjusted with a
pressure regulator (A).
Pull the pressure regulator upwards to make
adjustments.
Turn the knob clockwise to increase the pressure in
the machine, turn it counter clockwise to decrease.
OILER
Check the oil level in the oil reservoir (3).
Remove the oil reservoir.
Now refill the tank with a pneumatic oil with a
viscosity of SAE20.
Check the injection quantity of the oil through
the viewing glass (4).
Generally, the screw must be closed completely
in a clockwise direction and then opened again
about ¼ to ½ turn by turning it counter
clockwise.
WATER SEPARATOR
Check the water level in the separator (2).
Water is drained when the valve (B) is opened.
B
C
A
1
4
2
3
Summary of Contents for W142
Page 3: ...BEDIENUNGSANLEITUNG ATH W142 ...
Page 59: ...OPERATING INSTRUCTIONS ATH W142 ...
Page 115: ...MANUEL D UTILISATION ATH W142 ...
Page 171: ...NÁVOD K OBSLUZE ATH W142 ...
Page 227: ...MANUAL DE INSTRUCCIONES ATH W142 ...
Page 283: ...BEDIENINGSHANDLEIDING ATH W142 ...
Page 339: ...INSTRUKCJA OBŁSUGI ATH W142 ...
Page 395: ...NÁVOD NA OBSLUHU ATH W142 ...