b)
Wheel data and entries for calculating the imbalance:
The following data must be recorded in the DYN, STA and
ALU1 modes:
[A] Distance between wheel and machine
[B] Rim width
[D] Rim diameter
This data is recorded by positioning the gauge on the
wheel rim. The [A] and [D] data is automatically recorded
by the machine.
The rim width must then be entered using the [B+] / [B-]
buttons.
The following data must be recorded in ALU2 and ALUS
mode:
[A] Distance between the machine and the first adhesive
point
[B] Distance between the machine and the second
adhesive point
[D] Rim diameter
[dE] Rim diameter at the second adhesive point
All wheel values are recorded by the automatic plunge.
During the measurement process, firstly move the plunge
to the first point and then, after a brief wait, it can be
moved to the second point.
The [A]; [B]; [D] and [De] data is then automatically
recorded by the machine.
In this process, the ALUS programme does not need to be
selected in advance.