9.
The display shows [CAL.] – [15.0]
10.
This value can be changed using D+ / D-
11.
Confirm with [ALU].
12.
Then secure an appropriate wheel (e.g. 16”) on the machine
13.
Next, position the plunge on the edge of the wheel rim
14.
Press the ALU button
15.
The display shows [CAL.] – [End]
16.
If the display shows [CAL] – [10], this means that the
calibration has been unsuccessful and must be repeated.
2.9.11.
Service calibration of the width gauge (optional)
1.
Press the key combination STOP + OPT
2.
The display shown opposite will appear
+