® Copyright ATH-Heinl GmbH & Co. KG, 2019, All rights reserved / Misprints and technical changes reserved / As of: 2019-03
Manufacturer ATH-Heinl GmbH & CO.KG
- 22 -
In order to access the calibration system, you must press the key
combination shown opposite:
1.
First the F button and then the R button
2.
The CAL – CAL displays will appear and the indicator lights
flash.
3.
Only release the buttons when the indicator lights are
illuminated constantly
.
+
The first pass can then be started by turning the wheel.
Manual turning can be stopped as soon as the display shows “run”.
The machine will then measure the wheel imbalance.
The display shown opposite appears after the balancing process.
The braking process can now be initiated.
Attach the calibration weight (200 g) to the inside of the wheel rim.
The second pass can then be started by turning the wheel.
Manual turning can be stopped as soon as the display shows “run”.
The machine will then measure the wheel imbalance.