109
5
Emergency procedures
5.1
Emergency manual descent
Following a failure in the electrical system or hydraulic circuit, the platform
DESCENT manoeuvre can be performed from any height by means of the
emergency control at ground level.
In this case, the operator on the ground (remember that at least one operator
must be present at ground level to ensure the platform is used in safe
conditions) must pull the hydraulic valve control installed on the lifting cylinder.
Warning:
This mechanism must only be used in an emergency, i.e. electrical or
hydraulic failure.
Warning:
After using this control, push the knob towards the frame slightly and
make sure that the spring has brought the mechanism back to its original
position
Summary of Contents for 1090 EVO
Page 7: ...7...
Page 22: ...22...
Page 23: ...23...
Page 49: ...49 37 Combustion engine 38 Fuel tank 39 Bi levelling chassis 37 38...
Page 78: ...78...
Page 80: ...80...
Page 122: ...122 In this configuration the oil level must be as shown in the figure below A 60mm...
Page 144: ...144...
Page 145: ...145...
Page 146: ...146...
Page 147: ...147...
Page 148: ...148...
Page 149: ...149...
Page 150: ...150...
Page 151: ...151...
Page 152: ...152...
Page 161: ...161 8 ATTACHMENTS 8 1 Declaration of conformity...
Page 163: ...163 MANDATORY ROUTINE INSPECTIONS Date Observations Seal Signature...
Page 177: ...177 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment...