6.2.17
Checking the operation of the
“
Proactive levelling
”
safety valves
With the frequency indicated in the general chart, check the additional levelling
locking valves.
Remove the connectors from the solenoid valves and try to perform manual
levelling operations with the machine in the transport position.
All the movements must be prevented and the maximum pressure relief valves
of the hydraulic block will be activated.
Warning: At the end of the test, restore the connectors as before.
Warning: if the conditions indicated above are not met, do not use the machine
and contact a qualified technician trained by Almac Srl