134
6.2.13
Checking the operation of the Proactive levelling redundant
angle sensor
With the frequency indicated in the general chart, check the redundant angle
sensor of the Proactive Levelling system.
•
With the platform in the transport configuration, place the machine with
the frame tilted with respect to the horizontal by a value slightly greater
than 3° on the lateral. Keep pressed, by inserting a wedge, the limit
switch shown in the figure below
•
Try to perform the manual levelling operations; make sure that they are
all disabled.
•
Repeat the operation with the frame tilted with respect to the horizontal
with a value slightly greater than 3° on the longitudinal
•
Try to perform the manual levelling operations; make sure that they are
all disabled.
Warning: if the movements are not disabled, do not use the machine and
contact a qualified technician trained by Almac Srl