4.2
Machine operation
4.2.1
Starting the internal combustion engine
To start the internal combustion engine and the hydraulic pumps, use the
ignition key on the ground controls.
The key-switch functions are:
•
(CENTRAL): Machine off - electrical system not powered
•
(RH POSITION): The whole electrical system of the platform starts, including
the mobile push-button panel in the work platform. The ground controls are
excluded.
•
(LH POSITION): The whole electrical system of the platform starts. The
ground controls are automatically enabled and the push-button panel in the
work platform is disabled.
Then the control unit will begin to check the safety systems:
•
On the console, the lights 1-2-3-4 will turn on, together with a beeping sound
•
The 4 lights turn on
•
Once the check is complete and the machine is in the transport position and
levelled, only the lights 2-3 must stay on and the beeping must stop.
Once the check-control cycle has terminated, the engine can be started:
•
Turn the selector switch to the left (ON).
Summary of Contents for 1470-HE EVO
Page 7: ...PAGE 7...
Page 12: ...PAGE 12 Work area on tracks Travel not allowed Maximum inclination allowed 2 5020 5490 7500...
Page 27: ...PAGE 27...
Page 28: ...PAGE 28...
Page 34: ...PAGE 34 Warning Do not tighten the fixing belts too much so as not to damage the eye bolts...
Page 50: ...PAGE 50 8 Extendible basket pedal...
Page 57: ...PAGE 57 38 Chassis and stabilisers...
Page 74: ...PAGE 74...
Page 76: ...PAGE 76...
Page 77: ...PAGE 77...
Page 80: ...PAGE 80...
Page 138: ...PAGE 138...
Page 160: ...PAGE 160...
Page 161: ...PAGE 161...
Page 162: ...PAGE 162...
Page 163: ...PAGE 163...
Page 164: ...PAGE 164...
Page 165: ...PAGE 165...
Page 166: ...PAGE 166...
Page 167: ...PAGE 167...
Page 168: ...PAGE 168...
Page 178: ...PAGE 178 MANDATORY ROUTINE INSPECTIONS Date Observations Seal Signature...
Page 191: ...PAGE 191 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment...