| Micro M5 Manual | v2.0
Out of Parlour Linking a Master Tag
The Link Animals menu item allows the user to link animals (Or just an ear tag ready for the animal) by
scanning it in a stall, the routine also allows for linking a master tag which allows the user to test the feeders
and system at any point.
Press the Enter key
to enter the routine.
When entering the routine, the user can select
the stall to use for linking, this is done by using
the 2 and 6 keys to step up the stalls and the 4
and 8 keys to step down.
Once the desired stall is selected, press and hold the Shift key and then press the
Enter key.
The control will then display `MASTER SCAN`, the system will stop scanning the stalls, and scan only the
antenna selected, when a tag is read it will link it to the master tag and display linked. Press the Cancel key to
abort.
The control will then wait a second and return to the stall selection step. Pressing the Cancel key
will exit the routine.
Innovation In and Out of Parlour
LINK ANIMALS
OOP LINK ST 1
MASTER SCAN
Enter
Setup
Cancel
Reset
or
2
é
ABC
6
è
MNO
8
ê
TUV
4
ç
GHI
or
or
MASTER LINKED
Enter
Setup
Shift
+