Model
ASP 5,5
Type
ASP 5,5
Splitting force
55 kN (5.5 t) ± 10 %
Log length
max. 1050 mm
Log diameter
min. 100 – max. 300 mm
Stroke
≈
500 mm
Feed speed
ca. 0,06 m/sec.
Return speed
ca. 0,13 m/sec.
Hydraulic oil (max.)
4,0 litres
Hydraulic pressure
20 MPa (200 bar)
Electric motor performance (power consumption)
AC P
1
= 3500 W (S6-40%)
Threephase P
1
= 3000 W (S6-40%)
Power supply
AC 230 V ~ 50 Hz, 16 A inert
Threephase 400 V 3~ 50 Hz, 16 A
Dimensions
Length 740 x Width 500 x Height 1520 mm
Weight
ca. 96 kg
P
P
o
o
s
s
s
s
i
i
b
b
l
l
e
e
p
p
r
r
o
o
b
b
l
l
e
e
m
m
s
s
Problem possible
cause
remedy
Logs are not being split properly
(insufficient splitting performance)
⇒
The log is not positioned correctly
⇒
The log exceeds the maximum dimensions
or the wood is too hard for the
performance of the machine
⇒
Splitting blade does not split log
⇒
Hydraulic pressure too low
⇒
Release rods bent (hydraulic tappet not
quite pressed in)
⇒
Incorrect connecting lead (longer than 10
m or too small cable cross-section)
⇒
Reposition the log correctly
⇒
Cut the log to the required dimensions
⇒
Sharpen splitting blade, check for burrs or
notches
⇒
Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒
Arrange for manufacturer or authorised company
to adjust the rods
⇒
Use the correct connecting lead
Splitting column moves unsteadily
or with strong vibrations
⇒
Air in the circuit
⇒
Splitting column not sufficiently lubricated
or oiled.
⇒
Check the oil level and add more oil if necessary.
⇒
Lubricate splitting column or oil with
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not move
⇒
Hydraulic pump defective
⇒
To correct the problem, refer to the manufacturer
or other approved service centre.
Motor starts up but splitting
column does not move
⇒
Motor turns in wrong direction
⇒
Check the motor direction
Threephase: adjust the motor direction (s. page
18)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
Motor will not start
⇒
No electrical power
⇒
2-phase mode in threephase motor
⇒
Connection cable defective
⇒
Electric motor defective
⇒
Check the fuse.
⇒
Have fuse and lead checked by qualified
electrician.
⇒
Replace the connection cable or have it checked
by an electrician.
⇒
To correct the problem, refer to the manufacturer
or other approved service centre.